Processing chemicals should be handled in accordance with the precautions indicated on the boxes and labels of the respective chemicals.


*Always wear protective gloves and safety goggles when handling chemicals with the above indications. This is recommended even for chemicals without these indications. For greater protection, the use of a protective mask and apron is also recommended.
*Wash hands thoroughly after handling processing chemicals or solutions.
* Any spilled chemicals should be wiped up immediately.
*Use caution when mixing chemicals as certain mixtures may produce toxic gases.
*If you get any chemical on your skin or in your eyes, immediately flush the affected part with a great amount of water.
* If you swallow any chemical or get any in your eyes, seek medical attention immediately and show the physician the information printed on the box or label of the chemical(s) involved.
* In some countries, chemicals carrying a poison label ” are required by law to be stored under lock and key. You are responsible for ascertaining and complying with the regulations that apply in your country concerning the handling of poisonous substances.
*Store chemicals in a safe place out of reach of children.
*Waste solutions should be disposed of in accordance with the ordinances governing the handling of industrial waste products in your locale. The P1-R chemical in the CP-48S replenisher cartridge and the Component A of the P1 start-up chemical fall into the category of industrial waste. Should you have any questions concerning these chemicals, consult your service representative.

Special note should be taken regarding the following properties of the CP-48S chemicals.

*The P1-R chemical of the Replenisher Cartridge PC and Component A of the P1 Start-up Chemical These components contain P-phenylenediamine and may thus cause skin and eye irritation if improperly handled. They may be injurious to the health if swallowed.
* The P2-RA Chemical of the Replenisher Cartridge PC and Component A of the P2 Start-up Chemical These components cause oxidation of metals. They may produce harmful ammonia gas if mixed with a chlorine-based bleach (hypochlorite) or an alkaline (P1-R or N1-RA).
* The P2-RB Chemical of the Replenisher Cartridge PC and Component B of the P2 Start-up Chemical
These components may produce harmful ammonia gas if mixed with a chlorine-based bleach (hypochlorite) or an alkaline (P1-R or N1-RA). They may also produce harmful sulfur trioxide gas if mixed with an acid.
*FSC100 (Fuji Super Conditioner) This component contains dichloroisocyanurate and may thus produce harmful chlorine gas if mixed with an acid. It is injurious to the health if swallowed.
f
Share
t
Tweet
g+
Share
?
Fuji Frontier Digital Mini Lab Review
4:31 AM

Artikel Menarik Lainnya:

Room Conditions For Fuji Frontier M...
Room Conditions For Fuji Frontier M...
Fuji Frontier 370 Paper Jam Problem...
Fuji Frontier 370 Paper Jam Problem...
Frontier 370 message of problem is ...
Frontier 370 message of problem is ...
Fuji Frontier 590 Laser Replacement...
Fuji Frontier 590 Laser Replacement...
Fuji Frontier 550/570 Laser Replace...
Fuji Frontier 550/570 Laser Replace...
Fuji Frontier 500 Laser Replacement...
Fuji Frontier 500 Laser Replacement...

Belum ada komentar untuk "How To Processing Chemical (CP-48S) Handling On Fuji Frontier"

Post a Comment

Newer Post Older Post Home
Subscribe to: Post Comments (Atom)
Find Us :

Entri Populer

  • Fuji Frontier 390 Laser Replacement and Repair
      National Laser Company offers laser repair on Fujifilm’s Digital Minilab Frontier 390. National Laser has established a reputation o...
  • Fuji Frontier Image Problem Isolation Procedures and Remedies
    Image Problem Isolation Procedures and Remedies When an Error Occurs First, confirm the relationship between the encountered error and imag...
  • Fuji Frontier 370 Error Message W-1224
    Error Message W-1224 Frontier 370 If you see error 2529 sos detection failed massage in Fuji frontier 370, you can following below step. Che...
  • Frontier LP5700R Digital Lab System
      Front   A high volume, stand-alone printer processor with a compact footprint that produces up to 2,040 4R prints per hour and up ...
  • Fuji Frontier 550/570 Laser Replacement and Repair
      National Laser Company offers laser repair on Fujifilm’s Digital Minilab Frontier 550/570. National Laser has established a reputa...
  • Fuji Digital Minilab Frontier 570 Specification And Features
          Fuji frontier 570 printer can print (Media) 4R size 1700 copy per hour. Basically Frontier 550/570/590 between no far differen...
  • Fuji Frontier 550/570 Laser Replacement and Repair
       National Laser Company offers laser repair on Fujifilm’s Digital Minilab Frontier 550/570. National Laser has established a reputat...
  • How To Processing Chemical (CP-48S) Handling On Fuji Frontier
    Processing chemicals should be handled in accordance with the precautions indicated on the boxes and labels of the respective chemicals. *A...
  • Fuji Frontier 340 Laser Replacement and Repair
      National Laser Company offers laser repair on Fujifilm’s Digital Minilab Frontier 340. National Laser has established a reputation...
  • Frontier 370 message of problem is W-2411 Solution
        When your Frontier 370 show "Frontier 370 message of problem is W-2411" massage that means it say "paper remains in ...
Powered by Blogger.
Copyright 2013 Fuji Frontier Digital Mini Lab Review - All Rights Reserved
Design by Mas Sugeng - Published by Evo Templates