The error message "W-2604 Sorter malfunction.
 Probable Cause
.Sorter is not connected properly.
.Faulty horizontal sorter drive motor (M822) or harness
.Faulty sorter belt stop position sensor (D823) or harness.
.Faulty sorter belt unit storage motor (M823) or harness
.Faulty sorter belt unit storage position sensor (D825) or harness (M823 does not stop for several seconds.)
.Faulty vertical sorter drive motor (M825) or harness
.Faulty sorter tray position sensor (D820) or harness


Taken Action
1.Repair or replace harness, or replace the motor.
2.Repair or replace harness, or replace the sensor.
3.Repair or replace harness, or replace the motor.
4.Repair or replace harness, or replace the sensor.
5.Repair or replace harness, or replace the motor.
6.Repair or replace harness, or replace the sensor. 
f
Share
t
Tweet
g+
Share
?
Fuji Frontier Digital Mini Lab Review
4:34 AM

Artikel Menarik Lainnya:

Fuji Frontier 550/570 Laser Replace...
Fuji Frontier 550/570 Laser Replace...
Fuji Frontier 390 Laser Replacement...
Fuji Frontier 390 Laser Replacement...
Fuji Frontier 350/370 Laser Replace...
Fuji Frontier 350/370 Laser Replace...
Fuji Frontier 350/370 Laser Replace...
Fuji Frontier 350/370 Laser Replace...
FP150SC Film Processor
FP150SC Film Processor
Frontier LP5700R Digital Lab System
Frontier LP5700R Digital Lab System

Belum ada komentar untuk "The error message "W-2604 Sorter malfunction In Fuji Frontier"

Post a Comment

Newer Post Older Post Home
Subscribe to: Post Comments (Atom)
Find Us :

Entri Populer

  • Fuji Frontier 390 Laser Replacement and Repair
      National Laser Company offers laser repair on Fujifilm’s Digital Minilab Frontier 390. National Laser has established a reputation o...
  • Fuji Frontier Image Problem Isolation Procedures and Remedies
    Image Problem Isolation Procedures and Remedies When an Error Occurs First, confirm the relationship between the encountered error and imag...
  • Fuji Frontier 370 Error Message W-1224
    Error Message W-1224 Frontier 370 If you see error 2529 sos detection failed massage in Fuji frontier 370, you can following below step. Che...
  • Frontier LP5700R Digital Lab System
      Front   A high volume, stand-alone printer processor with a compact footprint that produces up to 2,040 4R prints per hour and up ...
  • Fuji Frontier 550/570 Laser Replacement and Repair
      National Laser Company offers laser repair on Fujifilm’s Digital Minilab Frontier 550/570. National Laser has established a reputa...
  • Fuji Digital Minilab Frontier 570 Specification And Features
          Fuji frontier 570 printer can print (Media) 4R size 1700 copy per hour. Basically Frontier 550/570/590 between no far differen...
  • Fuji Frontier 550/570 Laser Replacement and Repair
       National Laser Company offers laser repair on Fujifilm’s Digital Minilab Frontier 550/570. National Laser has established a reputat...
  • How To Processing Chemical (CP-48S) Handling On Fuji Frontier
    Processing chemicals should be handled in accordance with the precautions indicated on the boxes and labels of the respective chemicals. *A...
  • Frontier 370 message of problem is W-2411 Solution
        When your Frontier 370 show "Frontier 370 message of problem is W-2411" massage that means it say "paper remains in ...
  • Fuji Frontier 340 Laser Replacement and Repair
      National Laser Company offers laser repair on Fujifilm’s Digital Minilab Frontier 340. National Laser has established a reputation...
Powered by Blogger.
Copyright 2013 Fuji Frontier Digital Mini Lab Review - All Rights Reserved
Design by Mas Sugeng - Published by Evo Templates